MPRXCX® 331 Control 0.6/1 (1.2) kV

Beskrivelse

Beskrivelse

Standarder

  • Internasjonal
    IEC 60331-1 or 2; IEC 60092-350; IEC 60092-353; IEC 60092-376; IEC 60228; IEC 60331-2; IEC 60331-21 ; IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Applications

MPRXCX®331 armoured fire resistant control cables maintain circuit integrity in case of fire by meeting performances requirements from the IEC 60331 series for 90 minutes. They are used for detection and warning systems where enhanced mechanical protection and electrical screening (EMC) is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.

Design

 

1.   Conductor
      Stranded bare copper
      Class 2 

2.   Insulation 
      Mica + XLPE (cross-linked polyethylene)

      Optional: Special fire resistant HF 90 (halogen-free compound)
       with INFIT TM technology up to 4 mm²


 3.  Inner covering
      (lapped)

4.   Armouring
      Bare copper braid, separator tape (optional)

5.   Outer sheath

      Polyolefin SHF 1 (SHF2 on request)
      Colour: orange

 

Marking
 l NEXANS l MPRXCX 331  "n" x (or G) "s" 150/250 V 90°C IEC 60092-353

IEC 60332-3-22  Cat. A IEC 60331-21/1 ww/yy *CE*

+ metric marking

 

Core Identification

5 and above: all cores white coloured, printed with black numbers
Cables with 3 cores and more also with green-yellow core (has to be stated in order).


 

Karakteristikker

Karakteristikker

Konstruksjonsegenskaper

Konstruksjonsegenskaper

Halogenfri
IEC 60754-1
Leder fleksibilitet
Flertrådet, klasse 2

Dimensjonsegenskaper

Dimensjonsegenskaper

Antall ledere
-
Ledertverrsnitt
- mm²
Ytre diameter min.
- mm
Ytre diameter maks.
- mm
Vekt (ca.)
- kg/km

Elektriske egenskaper

Elektriske egenskaper

Tillatt belastning i luft
- A
Normert spenning i 3 fase systemer Uo/U
0,6/1 kV
Maks. driftsspenning
1,2 kV

Bruksegenskaper

Bruksegenskaper

Brannbeskyttet
IEC 60331-21
Flammehemmende
IEC 60332-3, kategori A
Korrosive gasser
IEC 60754-2
Røyktetthet
IEC 61034
Maks. tillatt ledertemperatur
90 °C
Minimum driftstemperatur
−35 °C
Min. installasjonstemperatur
−10 °C
Elektromagnetisk interferens motstand
Ja

Ressurser

Ressurser

Kontakt oss

Tema som du ønsker mer informasjon om:

Påkrevde felter*

Vennligst sjekk det du har lagt inn for feil

E-postadresse må inneholde @ tegnet

Personlig databeskytter

Det er din rett å nekte behandling og analyse av dine personlige data, og deres bruk til markedsføringsformål

Tusen takk!

Takk for at du kontaktet oss, vi tar kontakt med deg snarlig.

Feil

En feil har skjedd. Vennligst prøve igjen.

Lukk